Fire water tanks

CUBIC STORE · Applications

Fire water tanks

Industry · Free trade zones · Hotels

A water reserve that has to be ready the day it is needed: durable, corrosion-free and with the exact volume the system design requires.

Fire protection

Guaranteed water for emergencies

Sprinkler and hydrant systems rely on a dedicated water reserve, sized for the hazard and the duration the design requires. A tank that corrodes or loses volume puts the whole system at risk.

In Costa Rica, the Fire Department’s National Fire Protection Regulation (RNPCI) requires fire water tanks to comply with NFPA 22 and to have a suction hydrant for Fire Department use. Drawings are reviewed on the CFIA’s APC platform.

Permastore® glass-fused-to-steel tanks need no painting and keep their integrity for decades. CUBIC designs and installs them with suction, overflow and fill connections, ready to tie into the pump room.

  • Glass fused to steel

    Factory-fired glass coating on both faces: never painted, never reapplied.

  • Modular and bolted

    Fast, clean assembly with no site welding; expanded or relocated ring by ring.

  • Seismic design

    Structures designed for wind and earthquake loads under the Costa Rican Seismic Code.

  • Single point of responsibility

    CUBIC designs the foundation, installs and maintains: from calculations to commissioning.

Fire water tanks

Applications

Who they are for

  • Industrial plants Storage for sprinklers, hydrants and hose cabinets.
  • Free trade zones and parks Shared reserves for several buildings.
  • Hotels and condominiums Protection for public and residential buildings.
  • Warehouses and distribution centers Large volumes on a small footprint.
  • Combined reserve Tanks with a dedicated fire volume plus service volume.
  • Custom connections Suction, test return, overflow, drain and fill.

What Costa Rican regulations require

Regulation
RNPCI of the Fire Department, 2023 version
Technical standards
NFPA package mandatory; tanks per NFPA 22
Suction hydrant
Mandatory on every fire water tank
Location
6 m from combustible materials or behind a firewall
Volume
Design flow for the duration set by the applicable NFPA standard
Drawings
Reviewed on the CFIA’s APC platform
Maintenance
Per the applicable NFPA standard, with owner records

Track record

Backed by a 65-year-old manufacturer

Permastore® tanks made in the United Kingdom, with local design, installation and maintenance by CUBIC.

View projects
design life (ISO 15686)
30 years
expected service life
50+ years
manufacturer heritage
1959
countries with Permastore® tanks
110+

Frequently asked questions

Frequently asked questions

Which regulation governs fire water tanks in Costa Rica?

The Fire Department’s National Fire Protection Regulation (RNPCI), 2023 version, which makes the NFPA package mandatory and requires tanks to comply with NFPA 22 and to have a suction hydrant.

What is a suction hydrant?

A pipe permanently connected to the tank or water reserve that lets Fire Department units draft water to fight a fire. The regulation requires it on fire water tanks.

How large should a fire water tank be?

The fire protection design defines it, based on the occupancy hazard, sprinkler and hydrant flow and the required duration. CUBIC sizes the tank from that design calculation.

Can one tank serve both fire and service water?

Yes, as a combined reserve: the service outlet sits higher than the fire outlet, so the emergency volume always remains available.

Does it need maintenance?

Very little. The glass is never painted or reapplied. An annual inspection of bolts, seals and fittings is recommended, which CUBIC FIX carries out following the manufacturer’s protocols.